CR4000
Micro-module products
Back to Micro-Modules
CR4000
Micro-module products
CR4000
The CR4000 sealed cloud cabinet is equipped with a microenvironment system, power supply and distribution system, and cooling system inside. It can collect real-time operating conditions within the cabinet, features centralized monitoring and remote management capabilities for multiple nodes and outlets, fulfilling the deployment requirement of "one cabinet, one center." Suitable for scenarios where small and medium-sized enterprises lack basic server room infrastructure, it not only resolves the challenge of having no basic environment setup but also ensures the complete operation of hardware equipment systems. The cabinet body adopts a fully welded front and rear structure, achieving higher static load bearing capacity.
Technical specifications
Name Specification
Rack System Cabinet dimensions: Width * Depth * Height (mm): 600×1200×2000
Rack System Cabinet doors: single glass door, single sealed back door
Power Distribution System - System Input Input main switch: 63A (3kVA), 63A (6kVA), 80A (10kVA)
Power Distribution System - UPS Rack-mounted UPS - Capacity: 1kVA/2kVA/3kVA/6kVA/10kVA
Power Distribution System - UPS Rack-mounted UPS - Configuration: Single-phase 220VAC, 50Hz/60Hz
Power Distribution System - UPS Rack-Mount UPS - Power Factor: 0.9
Power Distribution System - UPS All-in-one lithium battery UPS: 6kVA/10kVA, DC240V, 15AH/20AH/25AH lithium battery.
Power Distribution Unit - PDU Mounting method: horizontal / vertical
Power Distribution Unit - PDU Type: Supports (GB standard, European standard)
Power Distribution System - Battery Lead-acid battery capacity: 9-250AH
Power Distribution System - Battery Number of Groups: 1-4
monitoring system Monitoring Host: CR1000 Series Smart Monitoring Host
monitoring system Temperature and humidity sensor: standard
monitoring system Monitoring System: Optional
monitoring system Smoke Detector: Standard
monitoring system Touchscreen: Standard
monitoring system Camera: Optional
monitoring system Audible and visual alarm: Optional
monitoring system SMS Alert: Optional
monitoring system Door Sensor: Standard
monitoring system Monitoring Platform: Standard
Fire protection system Fire unit: optional, smoke detector, audible and visual alarm, capable of fire linkage.
refrigeration system Cooling method: Direct-expansion air-cooled
refrigeration system Mounting Type: Rack-Mounted
refrigeration system Cooling capacity: 3-12 kW